- Qingqingquan
- Shandong
- 20 days
- 300 units per month
Dyeing plant reverse osmosis water purification equipment is highly efficient and stable, applicable to a variety of fields, the selection needs to focus on water quality matching and after-sales service, our company can provide customized solutions.
Dyeing Factory RO Water Treatment System
I. Dyeing Factory RO Water Treatment Equipment Overview
1. Definition:
• Reverse osmosis (RO) system that treats and produces 10 tons of pure water per hour, applicable to medium and large-scale water use scenarios.
2. Working Principle:
• High-pressure osmosis: water is pressed through a high-pressure pump (usually 4-8MPa) into a semi-permeable membrane (pore size 0.0001μm), which intercepts bacteria, viruses, heavy metals, organic matter and other impurities.
• Separation efficiency: pure water permeability ≥95%, adjustable wastewater ratio (1:1-1:3, depending on water quality).
Ⅱ. Dyeing Factory RO Water Treatment System Composition and Function
1. pretreatment system
• raw water pump: to provide stable inlet pressure.
• Multi-media filter: remove suspended solids and sediment (precision 50-100μm).
• Activated carbon filter: adsorb residual chlorine, organic matter (CTO cartridge life of about 6-12 months).
• Softening filter: reduce hardness through ion exchange (prevent RO membrane scaling).
2. Reverse osmosis system
• Core components: rolled RO membrane (such as Dow, Hydronic brand, life expectancy of 2-3 years).
• Auxiliary components:
• High-pressure pump (frequency conversion control, energy saving 10%-15%).
• Online monitoring instrument (conductivity, pressure, flow rate real-time display).
• Automatic flushing module (reduce membrane pollution).
3. Post-treatment system
• pH adjustment: add lye to neutralize acidic water (for industrial ultrapure water needs).
• Ultraviolet sterilization: further inactivate microorganisms (optional).
Ⅲ. Dyeing Factory RO Water Treatment System Core Advantages
1. Purification effect Removal rate ≥99.99% (bacteria, viruses, heavy metals)
2. Stability Fully automatic control, fault self-diagnosis and alarm
3. Maintenance Costs Filter cartridge annual replacement cost of about 5,000-10,000 yuan (depending on the quality of the water)
4. Energy saving Low-pressure membrane design, energy consumption is reduced by 20% compared with the conventional system
Ⅳ. Dyeing Factory RO Water Treatment System Application Scenarios
1.Industrial field
• Electronics industry: semiconductor cleaning, circuit board manufacturing (resistivity ≥ 10MΩ-cm).
• Pharmaceutical industry: water for injection, oral liquid preparation (in line with GMP standards).
2. Commercial Scenario
• Direct drinking water system for hotels and schools (support daily water consumption for 500-1000 people).
3. Special needs
• Boiler make-up water, laboratory ultrapure water pre-treatment.
V. Selection Guide
1. Water quality matching
• High hardness areas need to be strengthened pre-treatment (such as the addition of scale inhibitor injection device).
• Fluoride/arsenic water sources need to customize special membrane elements.
2. Brand and after-sales
Priority is given to manufacturers who have passed the ISO9001 certification
Ⅵ. Maintenance points
1. Daily inspection: pressure gauge fluctuation, conductivity abnormal alarm.
2. Regular maintenance:
• Clean RO membrane (citric acid chemical cleaning) every 3 months.
• Replace the precision filter (precision 5μm) every year.
Conclusion: Reverse osmosis equipment is a cost-effective choice for industrial and commercial water, the purchase of a comprehensive consideration of water quality, budget and long-term maintenance costs. Our company can provide customized solutions to ensure efficient and stable operation of the system.